KTE Plastics

560 County Road #3, Pierson, Fl.

#1. How does the KTE EQUAL DISTRIBUTION system work?

Like most properly installed conventional gravel absorption septic systems, the KTE EQUAL DISTRIBUTION system relies on the traditional outstanding performance produced by equal distribution of effluent. Our component enhancements, refined installation procedures and attention to installation detail produce the most accurately installed systems in the industry.


#2. How much time can be saved with KTE EQUAL DISTRIBUTION system installations?

The time savings gained with installing the KTE EQUAL DISTRIBUTION can be measured in two ways.

Drainfield Installations- A minimum time savings of 25% can be expected over conventional installations as a result of the precision, accuracy and simplicity of the KTE EQUAL DISTRIBUTION system.

Rework due to inspection failure- Virtually eliminated with proper KTE EQUAL DISTRIBUTION system installation.


#3. Are KTE EQUAL DISTRIBUTION systems ASTM approved?

KTE EQUAL DISTRIBUTION pipe and fittings meet ASTM F 405-97, Standard Specifications for Corrugated Polyethylene (PE) Pipe and Fittings.


System installations shall be in accordance with KTE Plastics installation instructions, ASTM F 481, and regulations of local health departments, regional, state and local agencies.


#4. How much more expensive is the KTE EQUAL DISTRIBUTION system than a conventional system?

The labor,time savings,accuracy & value gained with the installation of the KTE EQUAL DISTRIBUTION system more than offsets component prices.




#5. Are there any special tools needed for KTE EQUAL DISTRIBUTION system installations?

The patented KTE hangers are a vital component to successful installations. There are currently three (3) options for acquiring hangers.

Option #1. Purchase
Aluminum HD (A)- Recommended for manifold $47.50
Aluminum (B)-General purpose $20.00
Plastic (A)- ReUsable $ 2.95


Option # 2. Lease (Monthly)
Aluminum HD (A)- Recommended for manifold $ 3.00
Aluminum (B)-General purpose $ 1.95
Plastic (A)- ReUsable $ .50


Option # 3. Trial (15 Days)
Aluminum HD (A)- Recommended for manifold $ n/c
Aluminum (B)-General purpose $ n/c
Plastic (A)- ReUsable $ n/c



#6. When properly installed, do KTE EQUAL DISTRIBUTION systems meet all code requirements?

Currently all KTE EQUAL DISTRIBUTION components meet the requirements of the Florida Department of Health, Bureau of Water and Onsite Sewage Programs, Chapter 64 E-6, F.A.C. Standards for Onsite Sewage Treatment and Disposal Systems.


#7. What is the lead time for delivery of KTE EQUAL DISTRIBUTION systems?

Normally 5 to 7 Days.